Naslov Dimenzioniranje UPS uređaja i baterijskog sustava za podatkovni centar
Naslov (engleski) Sizing of UPS Device and Battery System for data Centre
Autor Stjepan Pavković
Mentor Ivica Pavić (mentor)
Član povjerenstva Ivan Pavić (predsjednik povjerenstva)
Član povjerenstva Nenad Debrecin (član povjerenstva)
Član povjerenstva Željko Tomšić (član povjerenstva)
Ustanova koja je dodijelila akademski / stručni stupanj Sveučilište u Zagrebu Fakultet elektrotehnike i računarstva Zagreb
Datum i država obrane 2021-07-15, Hrvatska
Znanstveno / umjetničko područje, polje i grana TEHNIČKE ZNANOSTI Elektrotehnika
Sažetak Sigurna opskrba energijom temelj je uspjeha i kontinuiteta mnogih poduzeća bilo da su to industrijska postrojenja, uredi, zdravstvene ustanove, komunalne službe ili podatkovni centri. Za neke od njih nestanci električne energije doista mogu biti vrlo skupi, a troškovi ponekad iznose i desetke milijuna eura. Zbog toga mnoge tvrtke instaliraju jedinicu za neprekidno napajanje (UPS).
Krucijalni dio UPS-a je baterijski sustav koja osigurava potrebnu energiju kako bi se osiguralo da kontinuirani protok čiste energije bude dostupan kritičnom procesu koji se napaja UPS-om. Parametri koje treba uzeti u obzir pri pravilnom odabiru sustava baterija su željena snaga i autonomija, učinkovitost pretvarača, konačno pražnjenje i raspoloživi napon punjenja. Ovi i mnogi drugi čimbenici moraju se pažljivo uzeti u obzir pri odabiru i konfiguriranju UPS- i baterija. Prilikom dimenzioniranja sustava za besprekidno napajanje napravljena je usporedba VRLA i litij-ionskih baterija te su opisani njihove prednosti i nedostaci.
Prilikom dimenzioniranja i projektiranja samog podatkovnog centra potrebno je u obzir uzeti mnogo čimbenika i parametara. Od same lokacije podatkovog centra u smislu zemljopisne širine, čime se utječe na rad i životni vijek baterija koje su osjetljive na ekstremne temperature, do zahtjeva kupca i vrsti tereta koji se štiti. Iz tih informacija možemo dobiti početnu viziju o zahtjevima i specifikacijama koje potrebni UPS treba ispunjavati. Odabir UPS-a se provodi na temelju informacija o stabilnosti u mreži na koju se priključuje i potrebnom stupnju zaštite kritičnog tereta. Ovisno o tome mogu se korisiti u dva UPS-a u paralelnom režimu rada.
Postoje tri osnovne topologije UPS-a. UPS dvostuke pretvorbe, mrežno interaktivni UPS i pasivni UPS. UPS dvostuke pretvorbe je najpouzdaniji odnosno nudi najsigurniju zaštitu kritičnom teretu. Jako bitan dio UPS-a je njegov baterijski sustav koji se sastoji od baterijskog kabineta, baterija te sustava nadzora i zaštite, te je svaki od ovih dijelova UPS-a potrebno pažljivo projektirati i dimenzionirati kako bi se izbjegli nepotrebni troškovi izgradnje, a naposlijetku i glavni razlog korištenja UPS-a, gubitci napajanja i nepravilnosti u napajanju.
Sažetak (engleski) A secure supply of energy is the foundation for the success and continuity of many enterprises be they industrial plants, offices, healthcare facilities, utilities or data centers. For some of these concerns, power outages can be very expensive indeed, with costs sometimes running into the tens of millions of euros. This is why many businesses install an uninterruptible power supply (UPS).
A critical part of the UPS is the battery bank that provides the energy needed to ensure that a continuous flow of clean power is available to the critical process that the UPS is powering. Parameters that have to be taken into consideration in properly selecting battery systems are the desired power and autonomy, inverter efficiency, final discharge, and available charging voltage. These and many other factors must be carefully considered when selecting and configuring UPSs and batteries. When dimensioning the uninterruptible power supply system, a comparison of VRLA and lithium-ion batteries was made and their advantages and disadvantages were described.
When dimensioning and designing the data center itself, many factors and parameters need to be taken into account. From the exact location of the data center in terms of latitude, which affects the operation and life of batteries that are sensitive to extreme temperatures, to requires of the customer and the type of load to be protected. From this information we can get an initial vision of the requirements and specifications that the required UPS needs to meet.
The choice of UPS is based on the information about the stability in the network to which it is included and the required degree of critical load protection. Independently, they can be used in two UPSs in parallel mode.
There are three basic UPS topologies. Dual conversion UPS, line-interactive UPS and passive UPS. UPS dual conversion is the most reliable, ie it offers the most secure protection to critical load. A very important part of the UPS is its battery system, which consists of a battery cabinet, batteries and monitoring and protection system, and each of these parts of the UPS must be carefully designed and dimensioned to avoid unnecessary construction costs, and ultimately the main reason for using the UPS, power losses and power irregularities.
Ključne riječi
Sustav neprekidnog napajanja
podatkovni centar
baterijski sustavi
baterije
VRLA
Li-ion
dimenzioniranje
proračun
opskrba
baterijska zaštita
Ključne riječi (engleski)
Uninterruptible power supply
data center
battery systems
batteries
VRLA
Li-ion
sizing
budget
supply
battery protection
Jezik hrvatski